0In the list
02Defects and testing

GOST 30340-2012: what it requires of a corrugated sheet

GOST 30340-2012 is the interstate standard for corrugated chrysotile-cement sheets and their fittings. It sets two profiles, dimensions and tolerances, strength, density, impact toughness, water tightness and frost resistance, and requirements for appearance, marking, acceptance and storage. It replaced GOST 30340-95 and, for corrugated sheets, GOST 8747-88 and GOST 30301-95.

Updated 5 min read

In short

5minutes to read

5sections

5sources

4catalog items

In this article

  1. 01What the owner and the buyer need to decide
  2. 02What is inside the standard
  3. 03How 2012 differs from 95
  4. 04Does the standard apply in your country
  5. 05How we do it

GOST 30340-2012 "Chrysotile-cement corrugated sheets. Specifications" is the main document by which corrugated slate is made and accepted in the countries that voted to adopt it. Among them are Uzbekistan, Kazakhstan, Kyrgyzstan and Tajikistan. The standard describes two sheet profiles, dimensions and tolerances, six physical and mechanical indicators, and appearance. It also sets marking, the quality document, acceptance rules, test methods, transport and storage. In 2013 it replaced GOST 30340-95. The test methods from GOST 8747-88 and the acceptance rules from GOST 30301-95 are now in it too, as far as corrugated sheets are concerned. A vote for an interstate standard does not yet mean it is mandatory in a particular country: that is checked in the country's own documents.

What the owner and the buyer need to decide

A standard is an agreement with the buyer: a sheet "to GOST 30340-2012" must pass all of its checks. For a plant this raises three questions:

  • Which indicators the line holds steadily and which are borderline. Strength and frost resistance depend on the mass, the felt, the press and curing. Appearance depends on the screens, cutting and demolding.
  • Whether there is anything to test with. The plant does some tests on every lot and some once a month or once a quarter. Without a bending press, an impact tester, a drying oven and a freezer, there is nothing to back the quality document with.
  • Which standard the buyers and the designs refer to. GOST 30340-95 and GOST 8747-88 still turn up in search results and in old designs. It is better not to cite them in new quality documents.

What is inside the standard

Profiles and designation

Sheets come in two profiles by wave height and pitch: 40/150 with symmetric edges and 51/177 with asymmetric edges. The number of waves is from five to eight. The sheet designation is made up of the profile, number of waves, length, width, thickness and the number of the standard. Ridge pieces, corners and valley pieces have their own fittings with their own abbreviations.

Dimensions and shape

The standard sets length, width, thickness, the height of the ordinary and edge waves, the width of the overlapping and overlapped edges, and the wave pitch. Separate tolerances are given for the squareness of the sheet and the straightness of the edges. A crooked wave or a skewed cut is already a non-conformity with the standard, even if the sheet is strong.

Physical and mechanical indicators

  1. The load the sheet carries without failure: with a punch (concentrated) or with a bar.
  2. Bending strength.
  3. Density.
  4. Impact toughness.
  5. Water tightness.
  6. Frost resistance: the sheet passes the set number of cycles, after which the specimens keep the required share of their strength and show no delamination.

For painted sheets, resistance of the coating to abrasion is added. The specific values for each profile are given in the tables of the standard. They should be taken from the text itself, not from retellings.

Appearance

Chips, holes, through cracks and delamination are not allowed. Minor defects, such as small scrapes, nicks and surface irregularities, are allowed within the limits the standard sets. On painted sheets the color is checked against a reference, and there must be no stains or efflorescence visible from a distance.

Raw materials and safety

The standard names the raw materials, chrysotile and Portland cement, and requires control of the specific activity of natural radionuclides. Machining the sheet produces dust. For that reason the standard requires respiratory protection and dust extraction and forbids abrasive processing. We give no assessments of harm here: that is a matter for the country's sanitary norms.

Marking, acceptance, storage

The marking is applied to the overlapped part of the sheet. Every delivery is accompanied by a quality document with the test results of the lot. A lot is the shift output of one line. Sheets are stored on level horizontal sites, painted ones under a roof. This is covered in detail in separate articles on marking and acceptance.

How 2012 differs from 95

The main difference is the arrangement of documents. Previously the specifications, test methods and acceptance rules lay in three standards. Now everything is collected in one. The title changed as well: "asbestos-cement" sheets became "chrysotile-cement". If a buyer or a design refers to GOST 30340-95, it is better to agree on a reference to the current standard. According to the Kazakhstan legal database prg.kz, GOST 30340-95 has lost force.

Does the standard apply in your country

Eight states voted to adopt GOST 30340-2012, including all four Central Asian countries that have slate plants. Whether it is mandatory is decided by national documents:

  • Kazakhstan. In the technical regulation on the safety of buildings and structures, building materials and products, GOST 30340 and GOST 18124 are in the list of standards applied voluntarily to meet its requirements.
  • Uzbekistan, Kyrgyzstan, Tajikistan. We did not find a national document for slate in open sources. Ask your country's certification body which standard it uses to accept your sheet.

How we do it

  • From the photo, dimensions and the passport of the felt or unit, we look for the item at the manufacturing plant. What we find, with the price, photos and specifications, we send before the order.
  • We inspect the lot at the plant before shipment: part number, dimensions, lot, packaging.

What this article relies on

Below are the documents and materials we refer to, so that you can check what is said for yourself.

Standards and documents

  • GOST 30340-2012 "Chrysotile-cement corrugated sheets. Specifications": profiles, indicators, appearance, marking, acceptance, methods, storage; the voting table; what it replacestext ↗
  • Record card of GOST 30340-2012 on meganorm.ru: status "in force", date of introduction 01.07.2013text ↗
  • GOST 30340-95 "Asbestos-cement corrugated sheets" — status "lost force" (prg.kz)text ↗
  • GOST 8747-88 "Asbestos-cement sheet products. Test methods" — partly replaced by GOST 30340-2012 and GOST 18124-2012 (prg.kz)text ↗
  • Order of the Minister of Industry and Infrastructure Development of the Republic of Kazakhstan No. 435 of 09.06.2023 "On approval of the Technical Regulation 'On the safety of buildings and structures, building materials and products'", Annex 2 (standards for voluntary application)text ↗

The values of the indicators by profile are in the tables of the standard; this is a retelling without figures.

Related catalog items

  • 001Fiber-cement and asbestos-cement sheet production line

    Fiber-cement and asbestos-cement sheet production line

    TMN-XHB-01Xinhuibo

  • 002

    Asbestos-cement forming felt 94047 · 1700 g/m²

    TMN-XHB-F01Xinhuibo

  • 003

    Needle-punched forming felt 51291 · 1000 g/m²

    TMN-XHB-F03Xinhuibo

  • 004Circular knife for trimming asbestos-cement sheet

    Circular knife for trimming asbestos-cement sheet

    TMN-280-1303

For slate plants

Felts, meshes and units for your line

We select from manufacturing plants in China by nameplate photo and machine dimensions. Send a photo of the plate and we will tell you what can be ordered.

Request

Ask about your machine

A part number is enough. A drawing or a photo of the unit speeds up sourcing but is not required.

Up to 3 files: photos (JPG, PNG, WEBP, HEIC) or PDF, up to 15 MB in total

By sending the request you consent to the processing of the data provided for the purpose of replying to it, as described in the Privacy Policy.