0In the list
03Slate technology

Slurry concentration in the vat: why it sets thickness and strength

Concentration is how much solid (cement, fibre, filler) there is in the water of the vat. It decides what film lies on the screen in one turn: a thicker slurry gives a thicker, denser film, a thinner one a thinner film. If the concentration wanders, the sheets come out with different thickness and different strength. It is held constant: recycled water is added by measurement, and measurements are taken regularly.

Updated 5 min read

In short

5minutes to read

5sections

8sources

3catalog items

In this article

  1. 01What the owner and the process engineer need to decide
  2. 02How concentration affects the sheet
  3. 03How concentration is measured
  4. 04What to check if the sheet thickness wanders
  5. 05How we do it
TableHow concentration affects the sheet4 rows →

Slurry concentration is the share of solid matter (cement, fibre, ground sand or filler) in the water standing in the vat of the sheet forming machine. The slurry for the Hatschek process is very thin: it has many times more water than solids. The thickness of the film the mesh cylinder lifts off in one turn depends on three things: the slurry level in the vat, its concentration and the speed of the screen. The machine speed and the level are usually held constant, so the main "steering wheel" of thickness is the concentration. If it jumps, the thickness, density and strength of the sheet jump. So the concentration is measured regularly, and recycled water is added by measurement, not by eye.

What the owner and the process engineer need to decide

  • Who is responsible for concentration. It is a shift parameter, not something for a setter once a month. The regulations should state: the target range for each type of sheet, the place and frequency of sampling, and who adjusts the water feed and how.
  • Manual measurement or a sensor. Manual sampling and weighing give an accurate but late answer. A sensor on the pipeline gives a continuous signal, but it has to be checked regularly against a manual measurement. On modern lines the control system itself adjusts the ratio of slurry to water from the thickness gauge on the wrap.
  • Spares for the circuit. Slurry and recycled water pumps, water feed gate valves and valves, vat agitators and the bucket agitator: whether the concentration can be held depends on their condition.

How concentration affects the sheet

If the slurry is...What is on the screenWhat is on the sheet
thicker than normalthe film is thicker per turn and gives up water worsethe sheet is thicker than specified, or is built in fewer turns; the layer is wetter before the drum, with a risk of delamination
thinner than normalthe film is thinner, more solids leave with the watermore drum turns are needed; output falls, load on the settling tank rises
uneven across the vatthe film has different thickness across the widthuneven thickness across the sheet, crooked wave
jumps over timethe film has different thickness along the length of the wrapsheets from one shift have different thickness and weight

Why a thin slurry works at all

In an asbestos-cement slurry, cement particles in water carry a negative charge and asbestos fibre a positive one, so the cement quickly settles onto the fibres. This is how the slurry becomes uniform and the cement stays on the screen together with the fibre. In a non-asbestos slurry with cellulose, cement retention on the screen is usually supported by a flocculant dosed according to the plant's recipe. If the slurry reaches the vat non-uniform, part of the cement leaves with the water through the screen and builds up in the recycled water.

Where the dilution water comes from

The slurry from the agitator is diluted to working concentration with recycled water, the water that has passed through the screen and settled. It always contains fine particles of cement and fibre. So the concentration in the vat depends not only on how much slurry and water were supplied, but on how clean the recycled water is. A badly working settling tank or recovery unit shifts the concentration unnoticed.

How concentration is measured

  1. Manual measurement. A sample of slurry of fixed volume is taken at a set place in the vat or chute, filtered, dried, and the solid residue is weighed. In the pulp and paper industry such a measurement is described in the TAPPI T 240 standard; at a slate plant the procedure is set by the laboratory in the regulations.
  2. A concentration sensor on the pipeline sends a signal to the control system. Its readings are checked regularly against the manual measurement.
  3. Indirectly, by the thickness of the wrap. If the machine builds a sheet of the specified thickness in a different number of turns than usual, check the concentration first.

What to check if the sheet thickness wanders

  • Whether the agitators in the vat work evenly: the slurry must not settle at the walls and edges. A building materials technology textbook names fluctuations in concentration as one cause of uneven sheet density and warping; extra agitators along the length of the vat are used against this.
  • Whether the chute and the distributor that spreads the slurry feed across the width of the vat are clogged.
  • Whether the recycled water feed is stable: whether the gate valve works, whether there is air in the pump.
  • Whether the cylinder screen is clean: a clogged screen picks up less slurry at the same concentration.
  • Whether the composition has changed: a new batch of cement, different fibre refining, more trimmings in the slurry.

How we do it

  • From a number, drawing or photo of the unit, we look for the item at the manufacturing plant. What we find, with the price, photos and specifications, we send before the order.
  • The line's automation system and separate slurry preparation units can be requested separately or as part of a line from the catalog.
  • We check the batch at the plant before shipment: article number, dimensions, batch, packaging.

What this article relies on

Below are the documents and materials we refer to, so that you can check what is said for yourself.

Reference materials

  • Rybyev I. A. "Building Materials Science" (Строительное материаловедение), section "Fundamentals of asbestos-cement product manufacturing": ratio of water to solids in the suspension, charges of cement and fibre, dilution of the slurry with recovered water in the chutestudme.org ↗
  • "Building Materials and Products" (Строительные материалы и изделия), § 8.14 "Production of asbestos-cement products" (bibliotekar.ru): dosing of water and solids for sheets and pipes, bucket agitatorbibliotekar.ru ↗
  • "Technology of Production of Building Materials, Products and Structures" (Технология производства строительных материалов, изделий и конструкций), clause 5.4.2 "Production of sheet products" (bibliotekar.ru): fluctuations in suspension concentration and vacuuming give uneven sheet density and warping; extra agitators along the length of the vatbibliotekar.ru ↗
  • Patent EP 0168191 "Process for making cement composite materials": film thickness depends on the slurry level, its consistency and the screen speedpatents.google.com ↗
  • Patent US 6824715: the slurry in the vat is thickened into a film on the screen, sheet thickness is set by the number of turns of the format drumpatents.google.com ↗
  • US Patent 5338357 "Fibre reinforced shaped solid articles": a flocculant (polyacrylamide) is added to the slurry before the Hatschek vat to retain cementpatents.google.com ↗
  • TAPPI T 240 "Consistency (concentration) of pulp suspensions": standard card (method for determining the concentration of fibrous suspensions)imisrise.tappi.org ↗
  • taminota.com catalog: PLC line automation system, manufacturing plant description (control of the slurry-to-water ratio from the actual thickness of the blank).

The "if the slurry is thicker or thinner" table is a conclusion drawn from the design of the machine and the sources named. The target concentration for your line is set by the process regulations.

Related catalog items

  • 001PLC-based line automation system

    PLC-based line automation system

    TMN-XHB-09Xinhuibo

  • 002Fiber-cement and asbestos-cement sheet production line

    Fiber-cement and asbestos-cement sheet production line

    TMN-XHB-01Xinhuibo

  • 003Vortex cleaner FSG-I … FSG-IX

    Vortex cleaner FSG-I … FSG-IX

    TMN-XHB-13Xinhuibo

For slate plants

Felts, meshes and units for your line

We select from manufacturing plants in China by nameplate photo and machine dimensions. Send a photo of the plate and we will tell you what can be ordered.

Request

Ask about your machine

A part number is enough. A drawing or a photo of the unit speeds up sourcing but is not required.

Up to 3 files: photos (JPG, PNG, WEBP, HEIC) or PDF, up to 15 MB in total

By sending the request you consent to the processing of the data provided for the purpose of replying to it, as described in the Privacy Policy.