Knife gate valve on the slurry and sludge line: wear and replacement
Knife gate valves are fitted on pipes carrying slurry, sludge and recycled water: the blade cuts through the suspension and keeps it from clogging the closure. The gland packing, the seat and the blade wear out, and on sludge valves with sleeves, the sleeves themselves. To replace one you need the nameplate, the seat type, the direction of installation, the flange connection and a description of the medium.
In short
9minutes to read
10sections
10sources
2catalog items
In this article
- 01What the chief mechanic should decide
- 02How a knife gate valve is built
- 03What seats there are
- 04Signs of wear
- 05Gland: tighten or replace
Contents
The pipes of a slate plant carry slurry, sludge and recycled water with cement, fiber and sand. Solids that settle in the cavities of a valve keep the closure from shutting. That is why knife gate valves are fitted on such lines. In them a thin flat blade with a sharpened edge drops across the flow, cuts through the suspension and sits on the seat. The manufacturer of one series writes directly that the design of the body and seat is intended to shut off media with suspended solids without clogging. In a knife gate valve the gland packing, the seat and the blade wear out, and in sludge valves with rubber sleeves, the sleeves themselves.
What the chief mechanic should decide
- Seat type for the medium. Metal, replaceable elastic, or rubber sleeves: what wears out and what to keep in stock depends on this.
- Unidirectional or bidirectional. A unidirectional valve is installed strictly by the mark: the pressure in the line must press the blade against the seat.
- Connection. The valve is fitted between the flanges of the pipe, and the hole pattern must match your flanges.
- Stock. The gland packing, the seat or the sleeves are kept in stock at the plant, and the blade is ordered together with them if it is scored.
How a knife gate valve is built
| Part | What it does | What happens to it |
|---|---|---|
| Body | holds the blade and the seat, fits between flanges | in lined bodies, wear of the lining |
| Blade (gate) | shuts off the flow, the edge is sharpened to cut through solids | scoring, wear of the edge |
| Seat | the blade sits on it in the closed position | wear, tears, the valve leaks when closed |
| Stuffing box (packing and gland follower) | keeps the medium from escaping outside along the blade | leak to the outside |
| Actuator | moves the blade: handwheel, gearbox, pneumatic cylinder, electric actuator | serviced according to its own instruction |
Knife gate valves have their own American standard, MSS SP-81. It describes valves of stainless steel or with a stainless-steel lining, bonnetless, with flanged ends, in sizes from DN 50 to DN 900, for service without shock loads. Pressure testing of the body and the closure is described in a separate standard, MSS SP-151. A valve may also be made to another standard, so the standard is taken from the passport of the particular valve.
What seats there are
| Seat | What it is for | What is replaced |
|---|---|---|
| Metal to metal | high temperature, dense media, cases where full tightness is not needed | when the seat wears, the manufacturer in our example prescribes replacing the whole valve |
| Replaceable elastic (EPDM, PTFE and others) | tight shut-off | the seat; if scored, the seat and the blade |
| Two rubber sleeves with a metal frame | abrasive pulps, sludge | the sleeves, the upper seal, the blade |
| Body with a polyurethane lining and a seat | abrasive media: manufacturers class polyurethane as protection against abrasion | when the lining wears, the body |
In a valve with sleeves, in the open position the sleeves are closed against each other. The flow goes through the full bore and does not touch the metal of the body. As it closes, the blade passes between the sleeves and is pressed by them. In some models the sleeves seal directly against the pipe flanges, and no gaskets are needed. The peculiarity of such valves is that with every stroke of the blade part of the medium comes out through the bottom of the body. That is how solids are washed out of the body. This is covered below, in the section on safety.
Against abrasion manufacturers offer coatings for the blade and parts: stellite, polyurethane. They also offer flushing ports, to wash solids out of the cavities of the body with water or air.
Signs of wear
| What you see | Probable cause | What to do |
|---|---|---|
| Gland leaks, blade clean | packing loosened or worn | tighten the gland follower; if that does not help, replace the packing |
| Gland leaks, blade scored | packing worn, blade damaged | replace the packing and the blade, check the seat |
| Leaks when closed, blade clean | seat worn | replace the seat (with a metal seat, the valve) |
| Leaks when closed, blade scored | seat and blade worn | replace the blade and the seat |
| Sleeve valve leaks through the bottom with the blade fully open or fully closed | sleeves worn or the stroke stop set wrongly | check the stops against the drawing, replace the sleeves |
| Leak at the top during the stroke of a sleeve valve | upper seal worn or the blade scored | replace the seal; if scored, the blade |
The table is made up from the instructions of knife gate valve manufacturers. For your model the procedure may differ, so check it against its passport.
Gland: tighten or replace
If the gland weeps, the nuts of the gland follower are tightened evenly and a little at a time, only until the leak stops. Over-tightened packing raises the force on the actuator and wears out faster. If the leak does not go away, the packing is replaced. The packing rings are laid one at a time and tamped with a wooden or plastic tool. Do not work with a sharp tool: it cuts the packing. The general rules for servicing glands are described in the article on glands and seals.
Installation
- The pipe flanges must be coaxial and parallel. Do not pull the pipes together with the valve.
- The bolts are tightened crosswise and evenly, to the torques from the valve instruction. The body often has blind threaded holes, so the bolt length is chosen so that they do not bottom out.
- A unidirectional valve is installed by the mark: at one manufacturer, the side with the inscription SEAT must be on the lower-pressure side when the valve is closed, so that the pressure presses the blade against the seat. Bidirectional valves can be installed either way round, but for some models the manufacturer still indicates a preferred direction by the same SEAT mark, so the instruction is read before installation.
- The flange pattern is checked before ordering. Manufacturers make valves for different flanges: for example, DIN PN 10 or ANSI B16.5 Class 150, others on request. One American manufacturer directly forbids fitting metric studs in holes for ASME Class 150. If the pipes at the plant are to GOST 33259-2015, say so in the request.
- The permissible pressure depends on the size. In the catalog of one series, a DN 50–125 valve is rated for 16 bar, and DN 700–1200 only for 2 bar. The pressure in your line is checked against the passport.
Storing spare valves and sleeves
Valves with sleeves are stored in the open position, away from sun and heat so that the rubber does not age prematurely, vertically if possible. After storage the valve is inspected: sleeves, blade, flange faces, actuator. If a valve stands closed in the frost for a long time, the manufacturer advises heating so that the sleeves work normally when it opens. Winter at the plant has an article of its own.
Safety
- Pressure. Before replacing the packing, the seat or the sleeves, the pressure in the line is relieved. The sleeves of the sludge valve in our example are replaced only with the valve removed from the line.
- Actuator. A pneumatic or electric actuator is switched off and locked out before servicing, so that the blade does not move under the hands.
- Release of the medium. On the stroke of the blade, a sleeve valve throws part of the sludge out through the bottom of the body. Above walkways and electrical equipment it is fitted with a drain plate or a shield, and the discharge is led to a drain. Do not plug all the holes of the drain plate: the manufacturer warns that this puts the upper seal out of action.
- Medium. Recycled water and sludge are strongly alkaline because of the cement, so safety glasses and gloves are needed during servicing. If the plant makes asbestos cement, the sludge may contain chrysotile fibers: work according to the occupational safety rules of your country for asbestos-containing materials.
What to send to order a replacement
- A photo of the nameplate and of the whole valve. From the nameplate we need the product number or serial number, model, DN size, pressure.
- Which part is needed: packing, seat, sleeves, blade, actuator. If there is a drawing with item numbers, the item number.
- Seat type and direction: unidirectional or bidirectional, where the SEAT mark is.
- Pipe flanges: standard, DN, pressure, number and diameter of holes, bolt circle diameter.
- What goes through the pipe: slurry, sludge or recycled water, temperature, pressure, asbestos cement or fiber cement.
- Actuator: manual or automatic, make and nameplate of the actuator.
How we do it
- From the photo of the nameplate, the dimensions and the description of the medium, we look for the valve or its parts at the manufacturing plant. What we find, with the price, photos and specifications, we send before the order.
- We work under a contract with the manufacturing plant. We inspect the lot at the plant before shipment: dimensions, flange pattern, seat and blade material, marking, packaging.
- Defects confirmed by a report are replaced: the replacement is supplied by the manufacturing plant under the contract.
What this article relies on
Below are the documents and materials we refer to, so that you can check what is said for yourself.
Standards and documents
- MSS SP-81-2021 "Stainless-Steel or Stainless-Steel-Lined, Bonnetless, Knife Gate Valves with Flanged Ends" — standard record: scope, DN 50–900, no shock loadstext ↗
- MSS SP-151-2021 "Pressure Testing of Knife Gate Valves" — standard record: pressure testing of the body and the closuretext ↗
- GOST 33259-2015 "Flanges for valves, fittings and pipelines for nominal pressure up to PN 250. Design, dimensions and general technical requirements" — standard recordtext ↗
Reference materials
- DeZURIK, instruction D11046 for KSL-SD slurry knife gate valves: sleeves, release of the medium on the blade stroke, drain plate, replacing the sleeves with the valve removed, storage, frost, faults, data for ordering partsdezurik.com ↗
- DeZURIK, instruction D11000 for KGN-MSU metal-seated valves: SEAT mark, installation, tightening and replacing the packing, faultsdezurik.com ↗
- DeZURIK, instruction D11023 for KGN-RSB bidirectional valves with a replaceable seat: installation, seat replacement, faultsdezurik.com ↗
- DeZURIK, instruction D11025 for KUL valves with a polyurethane lining: design, wear of the liningdezurik.com ↗
- ORBINOX, catalog of the VG series: sludge valve with rubber sleeves, leakage through the bottom in operation, flushing ports, flanges DIN PN 10 and ANSI B16.5 Class 150production.axflow.com ↗
- ORBINOX, catalog of the EK series: shut-off of media with suspended solids, seat types, pressure by size, coatings against abrasionproduction.axflow.com ↗
- Cooke A. M., Akers S. A. S., Leite J. V., Winter R. "Selection and performance of flocculants for Hatschek made air cured fibre cement", IIBCC 2010: recycled water of a Hatschek machine — a saturated solution of calcium hydroxide, strongly alkalineiibcc.biz ↗
The signs of wear and the servicing procedure are given from the instructions of particular manufacturers. For your valve, the passport of its manufacturer applies.