Aligning a motor with a pump or gearbox: tools and tolerances
After a motor, pump, gearbox or coupling is replaced, the shafts are set in one line. Alignment tolerances depend on speed: for a short elastic coupling at 1500 rpm the PRUFTECHNIK guide allows an offset of 0.09 mm and an angularity of 0.07 mm per 100 mm of coupling diameter. This is usually stricter than the tolerance of the coupling itself. Before alignment the soft foot is eliminated, and afterwards the result is recorded.
In short
8minutes to read
8sections
6sources
3catalog items
In this article
- 01What the mechanic needs to decide
- 02Offset and angularity
- 03Which tolerances
- 04Preparation: without it the alignment does not hold
- 05What to measure with
Contents
The motor, the coupling and the pump or gearbox must rotate about one axis. An elastic coupling accommodates a small offset but does not cancel it: what the coupling tolerates still loads the bearings, the seals and the elastic element itself. So after every replacement of a motor, pump, gearbox or coupling, after frame repair and when vibration grows, the shafts are set again. Alignment with a straightedge "by eye" is no more accurate than about 0.1 mm: that is the limit of the eye's resolution. For many drives this is not enough. Below — what to measure, which tolerances to take and how not to spoil the measurement.
What the mechanic needs to decide
- Whose tolerances to take. The tolerances of the machine manufacturer or of your plant standard come first. The general reference tolerances by speed — only if you have none of your own.
- What to measure with. A straightedge and a feeler gauge are good for rough setting. For the final alignment you need dial indicators or a laser instrument.
- Which one moves. The driven machine — the pump, the gearbox — is placed and fixed first, and the motor is set to its shaft.
Offset and angularity
Misalignment is described by two quantities, each in two planes, vertical and horizontal:
| Quantity | What it is | How it is expressed |
|---|---|---|
| Offset (radial) | the axes are parallel but shifted | mm in the plane of the coupling |
| Angularity (angular) | the axes cross at an angle | difference of the gaps between the half-couplings, mm per 100 mm of coupling diameter |
Angularity is easiest to understand through the gap: at the same angle a coupling of larger diameter has a larger difference of gaps at the rim. So the reference tolerances on angularity are given per 100 mm of diameter, and for your own coupling they are recalculated by its diameter.
Which tolerances
The PRUFTECHNIK shaft alignment guide gives suggested tolerances for short elastic couplings. These are the largest deviations from the target — from zero or from the calculated allowance for heating.
| Speed, rpm | Offset, mm: acceptable | Offset, mm: excellent | Angularity per 100 mm: acceptable | Angularity per 100 mm: excellent |
|---|---|---|---|---|
| 750 | 0.19 | 0.09 | 0.13 | 0.09 |
| 1500 | 0.09 | 0.06 | 0.07 | 0.05 |
| 3000 | 0.06 | 0.03 | 0.04 | 0.03 |
The same guide states that the permissible misalignment depends not only on speed but also on power, the type of coupling and of the machines, and that "excellent" alignment does not guarantee running without vibration. A rigid coupling allows no offsets: it is set as accurately as possible.
The coupling tolerance is not the alignment target
An elastic coupling has its own tolerance, and it is usually wider. For example, a ROTEX jaw coupling of size 38 allows a radial offset of 0.28 mm at 1500 rpm per the manufacturer's instructions, while the reference shaft alignment tolerance at the same speed is 0.09 mm. The shaft alignment tolerances protect the bearings and seals of the machines, the coupling tolerance protects the coupling itself. The ROTEX manufacturer states plainly that the permissible offsets of the coupling leave a margin for external influences in operation — thermal expansion and settling of the foundation. Setting a drive "to the coupling tolerance" means using up this margin at installation.
Preparation: without it the alignment does not hold
- Switch the drive off and protect it against starting. Remove the fuses or switch off the breaker, hang a prohibition sign. Work only with the shafts stopped.
- Clean the supporting surfaces. The frame and the supporting surfaces of the feet are clean, burrs are filed off.
- Check the runout of the half-couplings with an indicator. A half-coupling with runout can itself cause imbalance.
- Eliminate soft foot (see below).
- Shims. Under a foot, if possible, no more than three shims; ready shims of exact thickness are more convenient.
- Pipes. The pipes to the pump must be supported and must not pull the pump, but must be free for thermal expansion.
- Manufacturer's data. If in operation the machine heats up and rises, the manufacturer may set an allowance for cold alignment: then the target is not zero but this allowance.
Soft foot
Soft foot is when the machine does not stand on all its feet equally, like a chair on an uneven floor. At every tightening the machine settles differently, the alignment "floats", and tightening the bolts loads the casing and the bearing supports. Each foot is checked; the kind of gap under a foot is determined with a feeler gauge. In the tolerance table of the PRUFTECHNIK guide the limit of soft foot is 0.06 mm at any speed.
Procedure:
- Check all four feet.
- Start with the foot with the largest gap and determine the kind with a feeler gauge: a parallel gap is corrected with a shim, a wedge-shaped one with a wedge shim or by machining the foot or the frame.
- Correct by shimming under one foot, not under all at once.
- Begin the alignment when all the feet are within tolerance.
What to measure with
| Method | What it gives | Limitations |
|---|---|---|
| Straightedge across the half-couplings | rough setting | eye resolution about 0.1 mm; it is the coupling that is aligned, not the shafts |
| Feeler gauge in the gap between the half-couplings | angularity from the difference of gaps | on elastic couplings the same limitations as with the straightedge |
| Dial indicators | accurate alignment with shim calculation | bracket sag, play, indicator tilt, axial play of the shaft |
| Laser instrument | accurate alignment, calculation of corrections under the feet | the instrument itself is needed |
Indicators: what to check so as not to be misled
- Bracket sag. Always measure it, however rigid the bracket looks: assemble the same fixture on a straight pipe at the same distance, zero the indicators at the top, rotate the pipe down and write down the reading. It is taken into account in the bottom readings.
- The rule for checking the readings. The sum of the readings at 3 and 9 o'clock must equal the sum at 12 and 6 o'clock — for both the radial and the face indicator. If they do not match, the measurement is repeated.
- Play and tilt. Play in the mounting and an indicator not set perpendicular to the surface give a large error. Axial play of the shaft distorts the face readings unless two axial indicators are fitted.
Laser
A laser instrument is not bothered by bracket sag, the coupling does not have to be taken apart for measuring, and the result is obtained with the shafts turned less than a quarter of a turn. Such instruments, for example the SKF TKSA, have built-in tolerance tables by speed and a soft foot check program; the SKF instructions require checking soft foot on all feet.
The order when the drive has a gearbox
The driven machine is placed first, the next one is set to it: the gearbox to the driven machine, the motor to the gearbox. This way each unit is set to one already fixed.
What to record after alignment
The repair log gets:
- The date, the drive, who did it, what was measured with.
- The speed and the coupling type, which tolerances were taken.
- Offset and angularity in the vertical and horizontal planes — before and after.
- Soft foot for each foot and what was corrected.
- How many shims were left under each foot.
The record lets you compare at the next repair and see whether the frame is settling and the drive is drifting. If the coupling on one drive wears faster than on others, the first thing to look at is these records.
How we do it
- A motor, gearbox, pump or coupling for replacement we select at the manufacturing plant by the plate and the fit dimensions. Before the order we send what we found, with photos and specifications.
- We check that the new unit has the same axis height and the same fit dimensions, so that the alignment does not require reworking the frame.
- If the line has no alignment instrument, at your request we look for indicator fixtures or a laser instrument from a manufacturer.
- We inspect the batch at the plant before shipping; the manufacturing plant replaces defective goods under a report.
What this article relies on
Below are the documents and materials we refer to, so that you can check what is said for yourself.
Standards and documents
- KTR. ROTEX, operating and assembly instructions KTR-N 40210 JP: Table 11 — permissible offsets of the coupling (size 38 — 0.28 mm at 1500 rpm)text ↗
- KTR. ROTEX, instructions KTR-N 40210 FR, cl. 4.5: the coupling tolerances cover thermal expansion and settling of the foundation, checking with an indicator or feeler gauge; cl. 2.3: switch off the drive and protect it against startingtext ↗
Reference materials
- PRUFTECHNIK. A Practical Guide to Shaft Alignment, 2002 (PDF from the distributor Ludeca): tolerances for short elastic couplings by speed (pp. 18–20), preparation and the order of setting the machines, shims, runout of half-couplings, pipes, thermal growth (pp. 28–29), soft foot (pp. 29, 32), straightedge and feeler gauge (pp. 33–35), indicators and bracket sag (pp. 36–43), laser (p. 45)empoweringpumps.com ↗
- Fluke / PRUFTECHNIK. Shaft Alignment Tolerances: coupling tolerances are usually wider than shaft tolerances, shaft tolerances protect bearings and seals, the machine manufacturer's tolerances, cold alignment with an allowance for heatingfluke.com ↗
- SKF. TKSA 51, instructions for use (Spanish): built-in tolerances by speedcdn.skfmediahub.skf.com ↗
- SKF. TKSA 31 and TKSA 41, Instructions for use, cl. 6.3: soft foot is checked on all feetnonprod.docs.rs-online.com ↗
The alignment tolerances, the allowance for heating and the bolt tightening for your drive are taken from the machine passport and the coupling manufacturer's instructions; the reference values — when there are no passport ones.