Slate or profiled steel sheet: a slate plant's arguments
Against profiled steel sheet, slate has four honest arguments: it is noticeably quieter in rain, it does not rust, it conducts heat worse, and less condensate drips from it on the cold side. It has weak points too: the sheet is heavier, brittle under impact and careless installation, and the choice of colours is narrower. A slate seller does better to know both sides and talk to the buyer about the conditions of his roof, not about what is "better in general".
In short
5minutes to read
5sections
8sources
1catalog item
In this article
A roofing buyer in Central Asia almost always chooses between slate and profiled steel sheet (profnastil in Russian): a galvanised steel sheet with trapezoidal corrugations, often painted. Slate has its own arguments: it is quieter in rain and hail, it does not rust, it does not get as hot in the sun as thin steel, and less condensate drips from it on the inside of a cold roof. It has weak points too: the sheet is heavier, it breaks from impact and careless installation, and there are fewer colours. It helps a plant to know both sides and to talk to the buyer about his building: a house, a warehouse, a cowshed, a canopy.
What the owner and the sales department need to decide
- Which argument for which buyer. For a private house, noise and heat under the roof matter. For a farm or a poultry house, corrosion and condensation. For a warehouse or workshop, span, weight and speed of installation. The same sheet is sold with different arguments.
- Which arguments are confirmed. Some are in standards (frost resistance, watertightness), some in tests (rain noise), some only in manufacturers' advertising. Tell the buyer what you can show.
- How to cover the weak points. Installation instructions, the right fasteners, ridge and trim pieces in the kit, clear packing: these reduce breakage and claims.
- Compare the kit, not the sheet. The buyer counts the cost of the sheet. It is fairer to count the whole roof: sheet, fasteners, battens for the pitch and weight of the sheet, trim elements, labour, and for profiled steel in a dwelling also sound and vapour insulation.
Arguments for slate
Rain and hail noise
A thin steel sheet hardly damps its own vibration and rings under rain. Steel producers themselves admit it: their guides have separate advice on how to deaden roof noise with insulation and damping layers. A cement sheet is heavier and absorbs the impact of a drop better. In laboratory tests of agricultural roofs by the ISO 10140-5 method, a corrugated fibre cement sheet turned out noticeably quieter than a corrugated steel one. The tests were run by specialists of fibre cement manufacturers, which is worth bearing in mind, but the conclusion matches what steel producers write.
Corrosion
Slate has nothing to rust. Profiled steel is protected by zinc and paint, and its life depends on where it stands. Conditions are hardest in livestock buildings: moisture condenses on the cold underside of the roof, dissolves gases and dust, and this solution eats the coating from below. Steel producers state such conditions outright in their recommendations and warranties. Cut edges, scratches and fastener holes are vulnerable too.
Heat and cold
Steel conducts heat well: in summer the sheet gets scorching, in winter it freezes through. A cement sheet conducts heat worse and warms up more slowly. Under a cold roof without insulation this is noticeable, in a shed, under a canopy, in a workshop. In an insulated house the difference is smaller: the insulation does the work, not the sheet.
Condensation
On a damp night, drops fall from the underside of a cold steel sheet. A cement sheet can absorb part of the moisture and give it back later. Fibre cement manufacturers cite this as an advantage for farms. Profiled steel solves the same problem with an anti-condensation layer on the back or a vapour barrier, and this has to be taken into account in the comparison.
Frost and water
For slate, frost resistance and watertightness are standardised indicators in GOST 30340-2012: the sheet passes a test for a set number of cycles and for absence of leaks. The buyer can be shown the lot's test reports. Where leaks and frost damage come from is covered in separate articles.
Weak points of slate
- Weight. The sheet is heavier than steel, the battens must be made for its pitch and weight, and it is harder to lift onto the roof.
- Brittleness. An impact, wrong transport, walking on the sheet without a ladder board, over-tightened fasteners, and the sheet cracks. Profiled steel bends but does not split.
- Sheet length. Profiled steel is cut to the length of the slope; slate is laid with an overlap in several rows.
- Colour. The palette of coloured slate is narrower than that of coated steel.
- Working it. Cutting and drilling cement sheet produces dust. GOST 30340-2012 requires respiratory protection and dust extraction for machining, and the sheet must be cut with a bladed tool: the standard does not allow abrasive discs (angle grinders). This has to be written into the installation instructions.
How the plant should talk to the buyer
- Ask what the building is and whether there is insulation.
- For a farm or poultry house: corrosion and condensation. For a house without insulation under the roof and for a canopy: noise and heat.
- Show the lot's test reports and the marking on the sheet.
- Give installation instructions: batten pitch, overlap, fasteners, how to walk on the roof.
- Offer a kit: sheets, ridge pieces, fasteners.
How we do it
- From the photo, dimensions and the passport of the unit, we look for the item at the manufacturing plant. What we find, with the price, photos and specifications, we send before the order.
- We inspect the lot at the plant before shipment: part number, dimensions, lot, packaging.
What this article relies on
Below are the documents and materials we refer to, so that you can check what is said for yourself.
Standards and documents
- GOST 30340-2012 "Chrysotile-cement corrugated sheets. Specifications": frost resistance, watertightness, requirements for machining the sheettext ↗
- GOST 24045-2016 "Steel formed sheet profiles with trapezoidal corrugations for construction", record: cold-formed profiles of galvanised steeltext ↗
- NormaCS, news on the draft revision of GOST 24045 (wider range of protective coating types)text ↗
Reference materials
- Demanet C. et al., "Rain noise from agricultural roofing", ICSV24, 2017 (Institute of Acoustics): roof tests to EN ISO 10140-5; the authors are specialists of fibre cement manufacturersioa.org.uk ↗
- Lysaght (BlueScope), "Rain Noise Considerations for Steel Roofs": rain noise on a steel roof and ways to reduce itlysaght.com ↗
- McElroy Metal, note on using painted steel in livestock buildings (refers to U.S. Steel recommendations): corrosion from condensate with gases, the worst places being the underside of the roofmcelroymetal.com ↗
- Swisspearl, corrugated fibre cement sheets for agriculture: absorbing and releasing moisture, less condensation under the roof (manufacturer's material)swisspearl.com ↗
- Practitioners' discussion on buildhub.org.uk: anti-condensation layer on steel sheet, noise and insulationforum.buildhub.org.uk ↗
Figures for noise, heating and service life are not given in the article: they depend on the sheet, the building and the climate, and many are published by manufacturers of one of the sides.