Pumps
Roots vacuum pump
Maximum pumping speed15m³/min
- TAMINOTA part number
- TMN-RB-16A
- Manufacturer part number
- ZBK-16A
- Rated pumping speed
- 11 m³/min
- Rated vacuum
- 40 kPa
Purpose: creating vacuum in industrial process systems, vacuum drying, degassing and production equipment.
- Category
- Pumps
- Industry
- Asbestos and fiber cement · Corrugated board · Printing · Suits any industry
- Availability
- Ready at factory
What to send for selection
- 01Part number or the number on the nameplate
- 02Photos of the unit and its nameplate
- 03Model of the machine the unit is fitted to
- 04Quantity
Specifications
TMN-RB-16A
- Item number
- 2453
- Rotation speed
- 400 rpm
- Geometric chamber volume
- 42 L
- Inlet and outlet port diameter
- Ø200 mm
- Motor power
- 22 kW, 6 poles
- Weight
- 890 kg
How to get this item
- 01You send the part number or a nameplate photo
- 02You get the plant’s invoice and a lead time
- 03Inspection at the plant, delivery, documents
Related articles
- Pump nameplate: flow, head, speed and how to pick a replacementOn a centrifugal pump nameplate the key figures are flow Q in m³/h and head H in meters at rated speed. That is one point of its curve. A replacement is chosen by that point, the speed and the ports, not by motor power: a pump of the same power can give a different head.
- Vacuum boxes under the felt: what wears out in themIn a vacuum box the cover (polyethylene or ceramic strips), the slot edges and the seals at the ends and joints wear out. A worn cover cuts the felt, gives uneven suction and a sheet of varying thickness. Check them at every stop and keep cover strips in stock.
- Liquid ring vacuum pump: why vacuum drops and what to replace it withThe vacuum of a liquid ring pump most often drops because of the sealing water: it is too warm, too little of it, or the circuit is scaled. Next come air leaks in pipes and boxes, and wear of the pump itself. Choose a replacement by capacity at your vacuum, speed, connection and power, not by a similar brand.
- How much vacuum a sheet needs, and what too little or too much doesThe vacuum under the felt sucks water out of the film before it reaches the format drum. Too little vacuum and the film arrives wet, the layers press together poorly, and the sheet slumps and delaminates. Too much and the film dries out and bonds worse with the next layer, and the felt wears and clogs faster. There is no single number for all lines: the vacuum level is set by the regulations and watched by the gauge and by the sheet.
- Water ring pump nameplate: what 2BE, SK and VVN meanIn the VVN (ВВН) and SK designations, the number after the letters is the approximate capacity in cubic meters per minute: ВВН1-12 and SK-12 pump about 12 m³/min. In the 2BE designation the number is a size code, not the capacity: look it up in the manufacturer's table. For a replacement, the letters matter less than the capacity at your vacuum, speed, power, drive, ports and casing material.
- Where a slate plant's electricity goes and how to cut itMotors take most of the electricity at a slate plant: mills and edge runners, refiner, hydropulper, vacuum pumps, slurry and water pumps, compressor. Consumption is cut in three steps, not by one purchase: remove idle running and throttling, fit a frequency drive where the load varies, and when replacing a motor choose a suitable power and a high efficiency class. Reactive power compensation is a separate matter.
Request
Send a part number or a photo — we will find the factory
Items from the catalog · 1
- TMN-RB-16A · Roots vacuum pump